Go through the following to check drive of FM5 and FM6: COPIER > FUNCTION > PART-CHK > FAN if not working properly, replace the fan. If it’s 275 deg C or more, do not turn on the power before replacing the Film Unit. Go through the following: DISPLAY > ANALOG > FIX-E2 or DISPLAY > ANALOG > FIX-E3 if it’s less than 275 deg C, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR and then turn OFF and then ON the power. Sub Thermistor 1, 2 (TH1) detects 275 deg C or more for 0.2 sec. Description: Abnormal high temperature in Sub Thermistor 1, 2.NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR. It it’s 260 deg C or more, do not turn on the power before replacing the Film Unit. Go through the following: DISPLAY > ANALOG > FIX-C, or DISPLAY > ANALOG > FIX-E if it’s less than 260 deg C, go through the following to clear the error: COPIER>FUNCTION>CLEAR>ERR and then turn OFF/ ON the power. ![]() Main Thermistor 1, 2 (TH1) detects 260 deg C or more for 0.2 sec. Description: Abnormal high temperature in Main Thermistor 1, 2.